Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Acta odontol. venez ; 48(4)2010. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-682934

ABSTRACT

Evaluar la microdureza de las resinas Charisma (microhíbrida) y Z100 (híbrida) en relación a la profundidad de polimerización (8, 6, 4, 2 mm e 0 mm-superficial), la fuente de luz (Diodo emisión de luz-LED y Luz halógena de cuarzo-tungsteno-QTH) y los tiempos de análisis (inmediato, 24 h y 1 mes). Fueron testadas resinas Charisma (Kulzer) y Z100 (3M/ESPE). Para la realización del ensayo de microdureza fueron confeccionados 07 cuerpos de prueba de 8x2x4mm en matriz de carbono, con incrementos de 1mm cada y fotopolimerizados con los aparatos Optilux (Dabi Atlante) y LED (MMOptic). Los cuerpos de prueba fueron sometidos a los ensayos de dureza Vickers; inmediato, 24 horas y 1 mes después de la confección, almacenados en agua destilada y estufa a 37 1ºC. El análisis de microdureza fue realizada por medio del microdurómetro Shimadzu HMV-2000, con 5s de indentación y 500g de peso. La dureza fue evaluada en diferentes profundidades (superficie externa, 2, 4, 6 y 8 mm). Los resultados fueron estadísticamente significantes (p=5%) para todas las condiciones experimentales. Ambas resinas tuvieron la microdureza disminuida conforme el aumento de la profundidad y presentaron valores mayores con el aparato de luz halógena que con el aparato de diodo. La resina Z100 presento mayores valores de microdureza en relación a la resina Charisma. De acuerdo con los resultados, se puede concluir que cuanto mayor la profundidad menor la dureza y el aparato QTH proporcionó mayor grado de polimerización


To evaluate the microhardness of the resins Charisma (microhybrid) and Z100 (hybrid) in respect to the depth of polymerization (8, 6, 4, 2 mm and 0 mm-superficial), the source of light (Emitting Diode of light-LED and halogenous quartz-tungsten-QTH Light) and the analysis times (immediate, 24 h and 1 month). Resins Charisma (Kulzer) and Z100 were tested (3M/ESPE). For the accomplishment of the microhardness essay 07 were confectioned body-of-test of 8x2x4mm in carbon matrix, with increments of 1mm each and photopolymerised with Optilux devices (Dabi Atlante) and LED (MMOptic). The body-of-test was submitted to the essays of Vickers hardness; immediate, 24 hours and 1 month after the confection, stored in distiled water and heat 37±1ºC. The microhardness analysis was accomplished by means of the microdurometer Shimadzu HMV-2000, with 5s and 500g of load. The hardness was evaluated in different depths (external surface, 2, 4, 6 and 8 mm). The results were statistically significant (p=5%) for all the experimental conditions. Both resins had had the microhardness diminished as the increase of the depth and had presented bigger values with the device of halogenous light that with the diode device. The Z100 resin presented greaters values of microhardness in respect to the Charisma resin. In accordance with the results, it can be concluded that how much bigger the depth lesser the hardness and device QTH provided to greater polymerization degree


Subject(s)
Light-Curing of Dental Adhesives , Polymerization , Composite Resins/analysis , Composite Resins/therapeutic use , Dentistry
SELECTION OF CITATIONS
SEARCH DETAIL